editor.ajphr@gmail.com
9409046853
e-ISSN: 2321-3647
logo

American Journal of Pharmacy and Health Research

Keyword

Simultaneous equation Method.

Explore 2 research publications tagged with this keyword

2Publications
12Authors
1Years

Publications Tagged with "Simultaneous equation Method."

2 publications found

2015

2 publications

Development and Validation for the Simultaneous Estimation of Pioglitazone Hydrochloride and Glimipride in Mixed Dosage Form by UV- Spectrophotometric Method

RajiniTalla et al.
11/1/2015

A Simple, precise, accurate and economical spectrophotometric method was developed and validated for simultaneous estimation of Pioglitazone hydrochloride (PIO) and Glimipride(GLM) in combined dosage form. In simultaneous equation method, Pioglitazone hydrochloride (PIO) and Glimipride (GLM) were quantified using their absorptivity values at selected wavelengths, viz., 267nm and 227nm respectively. The linearity range was found to be 5-50μg/ml for Pioglitazone hydrochloride (PIO) and 5-50μg/mlGlimipride(GLM).The accuracy and reproducibility of the proposed method was statistically validated by recovery studies. The simultaneous equation method permits simple, rapid and direct determination of Pioglitazone Hydrochloride (PIO) and Glimipride (GLM) in commercially available combined dosage form without previous separations and analysis.

Analytical Method Development and Validation for the Simultaneous Estimation of Cefixime Trihydrate and Ornidazole in Combined Dosage form by UV-Spectrophotometric Method

K Veena et al.
10/1/2015

A Simple, precise, accurate and economical UV-spectrophotometric method has been developed and validated for simultaneous estimation of Cefixime trihydrate (CEF) and Ornidazole (ORD) in combined dosage form. In simultaneous equation method, CEF and ORD were quantified using their absorptivity values at selected wavelengths 288 nm and 311 nm respectively. The linearity range was found to be 5-50 μg/ml for CEF and 5-50 μg/ml for ORD. Different analytical parameters such as linearity, precision, accuracy, limit of detection (LOD) and limit of quantification (LOQ) were determined as per ICH guidelines. Limit of detection and quantification values CEF 1.10 and 3.33 μg/ml and for ORD 1.58 and 4.79 μg/ml respectively. The recovery values between prescribed limit of 98-102% shows that method is free from interference of excipients present in formulation. The developed method was free from interferences due to excipients present in formulation and it can be used for routine quality control analysis.

Keyword Statistics
Total Publications:2
Years Active:1
Latest Publication:2015
Contributing Authors:12
Whatsapp