editor.ajphr@gmail.com
9409046853
e-ISSN: 2321-3647
logo

American Journal of Pharmacy and Health Research

Keyword

Precision

Explore 2 research publications tagged with this keyword

2Publications
9Authors
2Years

Publications Tagged with "Precision"

2 publications found

2026

1 publication

UV-VISIBLE SPECTROPHOTOMETRIC METHOD FOR QUANTITATIVE ESTIMATION OF SULFAMETHOXAZOLE IN PHARMACEUTICAL DOSAGE FORM

Dr.Ganesh Akula et al.
6/9/2026
pp. 23-31

A simple UV–visible spectrophotometric method was developed and validated for the quantitative estimation of sulfamethoxazole in tablet dosage forms in accordance with ICH guidelines (ICH, 2005). The method employs filtered water as solvent and measurement of absorbance at 525 nm, with calibration curves showing good linearity over the concentration range of 5–30 μg mL−1μg mL−1. Absorptivity values were calculated at the selected wavelength. Accuracy, evaluated through recovery studies, showed percent recovery between 98.90 and 99.96% with %RSD values below 2%, confirming the reliability of the method. Precision studies (intra- and inter-day) yielded a %RSD of 0.678, while ruggedness assessment using six replicate absorbance measurements produced a %RSD of 0.253, indicating good robustness. All validation parameters met ICH acceptance criteria, demonstrating that the proposed method is simple, rapid, accurate, precise, and suitable for routine quality control analysis of sulfamethoxazole in pharmaceutical tablet formulations.

2022

1 publication

Development of A New RP-HPLC Method For Estimation of Aprepitant From Solid Dosage Form.

Prathap VR et al.
10/1/2022

ABSTRACTThe aim of the present work was to develop and validate a simple and efficient method for the analysis of Aprepitant in pharmaceutical dosage forms by reverse phase high-pressure liquid chromatography. A stainless steel column 75 mm long, 4.6 mm internal diameter filled with octasilyl silica chemically bonded with synthetic hybrid silica gel particles of 3.5 mm diameter was used for elution. The retention time of Aprepitant was 4.05 min. The method showed a good linearity in the concentration range of 0.02478 – 0.07434 mg/mL with a correlation coefficient of 0.9999. The validation characteristics included specificity, linearity, limit of detection, limit of quantification, precision, robustness and stability. Validation acceptance criteria were met in all cases. The method could be successfully used for the analysis of Aprepitant in pharmaceutical dosage forms. Keywords: Aprepitant, Accuracy, Precision, Linearity, Mobile Phase and Validation

Keyword Statistics
Total Publications:2
Years Active:2
Latest Publication:2026
Contributing Authors:9
Whatsapp